| LED linear light | Long, even illumination in hazardous-area corridors, process spaces, and service areas. | Only a model specifically certified with EPL Ga for the applicable gas atmosphere. | Choose a certified model with EPL Gb or Ga. | Choose a certified model with EPL Gc, Gb, or Ga. | Check the certificate, gas group, temperature class, ambient-temperature range, corrosion resistance, and ingress-protection rating. |
| LED bulkhead light | Compact general lighting for passageways, machinery spaces, and exterior work areas. | Only where the exact model’s certificate permits Zone 0 use and EPL Ga. | A certified EPL Gb or Ga version may be suitable. | A certified EPL Gc, Gb, or Ga version may be suitable. | Consider vibration resistance, lens protection, cable-entry compatibility, and salt-spray exposure. |
| LED floodlight | Broad-area illumination for loading areas, tank-deck work, and maintenance operations. | Use only a specifically Ga-certified model approved for the location. | Use a model certified for Zone 1, typically EPL Gb or Ga. | Use a model certified for Zone 2 or a higher protection level. | Verify beam distribution, mounting strength, glare control, heat dissipation, and hazardous-area certification. |
| LED high-bay light | Overhead lighting in high-ceiling spaces such as enclosed process or service areas. | Only a model whose IECEx certification explicitly includes EPL Ga and the relevant conditions. | A Zone 1-certified EPL Gb or Ga model is required. | A Zone 2-certified EPL Gc, Gb, or Ga model may be suitable. | Check ceiling height, light distribution, ambient temperature, suspension method, and maintenance access. |
| Emergency bulkhead light | Emergency escape-route or backup lighting in hazardous areas. | Only if the complete emergency-light model is certified for Zone 0 with EPL Ga. | Confirm both hazardous-area certification and emergency-lighting performance for the intended zone. | Confirm the certified zone, emergency duration, battery arrangement, and test method. | Check whether the battery is integral or remote, required emergency duration, charging conditions, and applicable vessel rules. |
| Portable hand lamp | Temporary inspection and maintenance lighting in tanks, voids, and service spaces. | Only a portable model specifically certified for Zone 0 and EPL Ga. | Select a certified portable light with EPL Gb or Ga and an approved power source. | Select a certified model with EPL Gc or higher, as required by the area classification. | Check the complete assembly, including battery, charger, cable, and accessories; use only as permitted by its certificate. |
| LED pendant light | Suspended lighting over workstations or equipment where ceiling-mounted fittings are impractical. | Only a pendant assembly certified for Zone 0 and EPL Ga. | Use a certified Zone 1 assembly; confirm the suspension and cable-entry arrangement are covered. | Use a certified Zone 2 or higher assembly suitable for the installation. | Assess suspension load, vibration, cable support, corrosion, and the exact installation instructions. |
| Low-profile deck or step light | Low-level illumination on walkways, steps, and deck edges. | Only a model explicitly certified for Zone 0 with EPL Ga. | Use a Zone 1-certified model where required by the area classification. | Use a Zone 2-certified model or one with a higher EPL. | Consider impact resistance, water exposure, drainage, slip hazards, and whether the fitting can be safely maintained. |
| Portable inspection light | Close-up inspection of machinery, valves, and equipment during maintenance. | Only a complete inspection-light unit certified for Zone 0 and EPL Ga. | Confirm the model is certified for Zone 1 and the intended gas group and temperature class. | Confirm Zone 2 certification and suitability of its power supply and accessories. | Check cable or battery configuration, handle temperature, drop resistance, and restrictions on use or charging. |
| LED searchlight or spot floodlight | Directional illumination for inspection, transfer operations, and exterior work. | Only a model specifically certified for Zone 0 and EPL Ga; availability may be limited. | Use a model certified for Zone 1, including its mounting and electrical connections. | Use a model certified for Zone 2 or a higher protection level. | Check beam reach, aiming and locking mechanisms, vibration resistance, and whether the full assembly is certified. |