| 1 | Compact Inverter ARC 160 | Single-phase, 220–240 V AC, 50/60 Hz | 160 A at 25% duty cycle | 20–160 A | 60% at 100 A, 40 °C | 1.6–3.2 mm | Manual metal arc welding with hot start, arc force, and anti-stick functions | Thermal overload, over-current, under-voltage, and over-voltage protection | IEC 60974-1; IEC 60974-10; applicable local electrical regulations | IP21S | Light fabrication, repair work, gates, brackets, and general maintenance | Clean ventilation paths every 1–3 months; inspect electrode holder, earth clamp, and cables | Confirm plug type, supply tolerance, local certification, and availability of replacement fans and cables |
| 2 | Portable Inverter ARC 200 | Single-phase, 220–240 V AC, 50/60 Hz | 200 A at 30% duty cycle | 20–200 A | 60% at 155 A, 40 °C | 1.6–4.0 mm | Manual arc welding with adjustable arc force, hot start, and digital current display | Thermal shutdown, fan cooling, anti-stick, and no-load voltage control | IEC 60974-1; IEC 60974-10; EMC requirements for the destination market | IP21S | Construction repairs, agricultural equipment, small steel structures, and field service | Keep dry, remove conductive dust, check output terminals, and test the cooling fan periodically | Check generator compatibility, maximum input current, transport protection, and warranty service location |
| 3 | Industrial Inverter ARC 250 | Single-phase, 220–240 V AC, 50/60 Hz | 250 A at 35% duty cycle | 20–250 A | 60% at 190 A, 40 °C | 2.0–5.0 mm | Manual arc welding with digital parameter control, hot start, arc force, and remote-control connection | Thermal, over-current, input under-voltage, and output short-circuit protection | IEC 60974-1; IEC 60974-10; IEC 60529 for enclosure classification | IP23S | Medium-duty structural work, pipelines, workshops, and equipment repair | Inspect internal dust accumulation at least quarterly; tighten terminals and verify calibration annually | Verify continuous input capacity, earthing arrangement, service documentation, and spare control boards |
| 4 | Three-Phase ARC 315 | Three-phase, 380–415 V AC, 50/60 Hz | 315 A at 60% duty cycle | 20–315 A | 100% at 245 A, 40 °C | 2.5–6.0 mm | Heavy-duty manual arc welding with stable current control and optional remote adjustment | Thermal overload, phase-loss detection, over-current protection, and output short-circuit protection | IEC 60974-1; IEC 60974-10; IEC 60529; local three-phase installation rules | IP23S | Steel frames, heavy machinery, shipyard repair, and production workshops | Use scheduled compressed-air cleaning; inspect contactors, terminals, grounding, and cooling airflow | Confirm phase sequence, rated site voltage, breaker size, lifting provisions, and authorized technical support |
| 5 | Generator-Compatible ARC 200 | Single-phase, 220–240 V AC, 50/60 Hz; generator-compatible design | 200 A at 30% duty cycle | 20–200 A | 60% at 155 A, 40 °C | 1.6–4.0 mm | Manual arc welding with input-voltage compensation, hot start, and anti-stick control | Input surge protection, thermal shutdown, over-current protection, and voltage fluctuation tolerance | IEC 60974-1; IEC 60974-10; applicable generator and electrical safety requirements | IP23S | Remote construction, infrastructure maintenance, outdoor repair, and utility work | Protect from rain and mud; clean air vents frequently; inspect extension leads and generator connections | Confirm minimum generator rating, permissible voltage fluctuation, plug configuration, and outdoor-use limitations |
| 6 | Multi-Process ARC/MMA 250 | Single-phase, 220–240 V AC, 50/60 Hz | 250 A at 35% duty cycle | 20–250 A | 60% at 190 A, 40 °C | 1.6–5.0 mm | Manual arc welding with lift-TIG capability, digital display, hot start, and adjustable arc force | Thermal overload, over-current, anti-stick, output short-circuit, and fan-on-demand control | IEC 60974-1; IEC 60974-10; IEC 60974-3 where applicable to arc striking devices | IP21S | Fabrication shops requiring electrode welding and occasional maintenance TIG work | Clean the torch and electrode connections; inspect gas fittings if lift-TIG is used; check display operation | Confirm included accessories, TIG torch compatibility, gas connection standards, and software or control-board support |
| 7 | Automatic Seam-Tracking ARC 315 | Three-phase, 380–415 V AC, 50/60 Hz | 315 A at 60% duty cycle | 40–315 A | 100% at 245 A, 40 °C | 2.5–6.0 mm | Mechanized electrode welding with travel carriage, adjustable travel speed, and basic seam-tracking control | Emergency stop, thermal overload, travel-limit switches, phase-loss protection, and grounding provision | IEC 60974-1; IEC 60974-10; ISO 13850 for emergency-stop principles where machinery controls apply | IP23S | Long straight seams, storage tanks, steel beams, and repetitive fabrication | Lubricate carriage guides; inspect wheels, limit switches, control cables, and electrode-feed components | Evaluate control-system language, operator training, replacement sensors, installation support, and spare-part lead time |
| 8 | Heavy-Duty ARC 400 | Three-phase, 380–415 V AC, 50/60 Hz | 400 A at 60% duty cycle | 40–400 A | 100% at 310 A, 40 °C | 3.2–6.0 mm | High-current manual arc welding with digital control, remote operation, and anti-stick function | Thermal overload, phase-loss, over-current, over-temperature, and output short-circuit protection | IEC 60974-1; IEC 60974-10; IEC 60529; national workplace electrical-safety rules | IP23S | Heavy structural steel, pressure-equipment fabrication, ship repair, and mining maintenance | Monthly visual inspection; quarterly internal cleaning; annual electrical safety and output-current verification | Check site transformer capacity, cable cross-section, grounding, lifting method, ventilation, and service response time |
| 9 | Low-Voltage ARC 250 | Single-phase, 110–120 V AC or 220–240 V AC, model-dependent | 250 A at 25% duty cycle on 220–240 V input | 20–250 A | 60% at approximately 160–190 A, 40 °C, depending on input voltage | 1.6–5.0 mm | Manual arc welding with automatic input-voltage selection on compatible versions | Under-voltage, over-voltage, thermal, over-current, anti-stick, and overload protection | IEC 60974-1; IEC 60974-10; destination-country electrical certification requirements | IP21S | Worksites with unstable power, maintenance teams, workshops, and small fabrication operations | Use correctly rated extension cables; inspect input selector or auto-sensing circuit; keep vents unobstructed | Confirm the exact voltage version, plug and fuse requirements, maximum input current, and local conformity marking |
| 10 | Enclosed Production ARC 500 | Three-phase, 380–415 V AC, 50/60 Hz | 500 A at 60% duty cycle | 50–500 A | 100% at 390 A, 40 °C | 3.2–8.0 mm | Production-grade manual or mechanized arc welding with remote control, parameter memory, and thermal monitoring | Emergency stop, thermal overload, phase-loss, over-current, output short-circuit, and enclosure interlock provisions | IEC 60974-1; IEC 60974-10; IEC 60529; applicable machinery and workplace safety standards | IP23S | Large steel structures, pressure vessels, heavy equipment, and continuous industrial production | Follow a documented preventive-maintenance plan; inspect cooling systems, power connections, controls, and insulation | Assess total ownership cost, commissioning, operator training, spare-module availability, warranty terms, and local service capability |