| 1 | Rated output power | 1.5 mechanical horsepower is approximately 1.12 kW (about 1,119 W). | Confirms the stated rating refers to motor output, not electrical input power. |
| 2 | Rated voltage and current | These are model-specific values; check the motor nameplate and matching drive documentation. | Ensures the motor and its electronic drive are compatible with the available power supply. |
| 3 | Rated speed | Obtain the rated speed in r/min from the datasheet; it cannot be determined from horsepower alone. | Speed affects the required torque, application fit, and drive settings. |
| 4 | Rated torque | For power in kW and speed in r/min: torque (N·m) ≈ 9,550 × power (kW) ÷ speed (r/min). | Allows a like-for-like comparison when candidate motors have different rated speeds. |
| 5 | Motor and drive compatibility | A brushless motor requires electronic commutation; verify the specified drive, feedback device, and wiring arrangement. | A motor may not operate correctly with an incompatible controller or feedback configuration. |
| 6 | Duty rating | Check the duty type stated under IEC 60034-1; S1 denotes continuous running duty under the specified conditions. | Helps establish whether the motor is specified for the application’s operating cycle. |
| 7 | Ingress protection | Read the complete IP code on the nameplate or datasheet; IP codes classify protection under IEC 60529. | Indicates specified protection against access, solid objects, and water ingress. |
| 8 | Insulation and temperature limits | Request the insulation thermal class and permitted ambient or winding-temperature limits for the exact model. | Supports evaluation of thermal suitability under the intended load and environment. |
| 9 | Efficiency and test conditions | Compare documented efficiency results with their stated voltage, speed, load, and test method. | Efficiency varies with operating conditions and should not be inferred from the horsepower rating. |
| 10 | Dimensions, mounting, and documentation | Confirm shaft, mounting, outline dimensions, wiring diagram, datasheet, and applicable test or conformity documents for the quoted model. | Prevents fit, connection, and verification issues when comparing supplier quotations. |