| 1 | EMI shielding and enclosure design | Radiated emissions escaping from equipment, or external RF fields coupling into it. | Use conductive enclosure materials or coatings, maintain electrical continuity across seams, and manage apertures, access panels, and cable entries. | Control cabinets, drives, communication equipment, and measurement systems. | Radiated emissions and radiated RF immunity testing, as applicable. |
| 2 | Power-line and signal-line filtering | Conducted RF noise and switching noise travelling along power or signal wiring. | Select input filters, common-mode chokes, capacitors, or ferrite components suited to the circuit; place filters near cable entry points and keep filtered and unfiltered wiring separated. | Switch-mode power supplies, PLC panels, motor drives, and industrial controllers. | Conducted emissions and conducted RF immunity tests, where required. |
| 3 | Grounding and equipotential bonding | Unwanted voltage differences, common-mode currents, and poor high-frequency return paths. | Bond conductive panels and equipment frames appropriately, use short and low-impedance connections, and follow the installation’s protective-earthing design. | Factory automation, machine tools, distributed control systems, and cabinet installations. | Installation inspection, bonding continuity checks, and EMC tests on the assembled system. |
| 4 | Cable routing and separation | Crosstalk and coupling between high-noise power circuits and sensitive control or measurement circuits. | Separate power, motor, and low-level signal cables; cross cables at right angles where practical; use suitable cable trays and avoid unnecessary loop area. | Production lines, servo systems, variable-speed drive installations, and sensor networks. | Wiring review and functional checks during representative equipment operation. |
| 5 | Surge and transient protection | Short-duration overvoltage events on power and signal ports, including switching-related surges. | Coordinate surge-protective devices with the port, installation category, earthing arrangement, and upstream protection; protect exposed signal interfaces where needed. | Outdoor equipment, long cable runs, industrial power inputs, and remote I/O. | Surge immunity testing, commonly addressed by GB/T 17626.5 / IEC 61000-4-5. |
| 6 | ESD protection and design | Electrostatic discharges to accessible surfaces or nearby conductive parts. | Select suitable interface protection, control discharge paths, review enclosure openings and touch points, and avoid sensitive circuit routing near likely discharge locations. | Operator panels, industrial computers, handheld terminals, and control interfaces. | ESD immunity testing, commonly addressed by GB/T 17626.2 / IEC 61000-4-2. |
| 7 | Fast transient and burst immunity | Repetitive fast transients coupled onto power, control, or signal connections. | Improve port filtering and decoupling, manage cable shields and bonding, and verify reset, alarm, and recovery behaviour during disturbances. | Relay-controlled equipment, industrial control cabinets, and systems near inductive loads. | Electrical fast transient/burst testing, commonly addressed by GB/T 17626.4 / IEC 61000-4-4. |
| 8 | RF immunity and interface hardening | Malfunction caused by radiated or conducted radio-frequency fields. | Improve enclosure and cable-entry shielding, filter vulnerable ports, strengthen interface protection, and test the equipment in defined operating modes. | Equipment installed near radio transmitters, wireless systems, or high-frequency industrial processes. | Radiated RF immunity and conducted RF immunity testing, as applicable. |
| 9 | Power-quality disturbance immunity | Voltage dips, interruptions, and variations that may interrupt operation or cause unintended states. | Define safe behaviour during supply disturbances, review hold-up and restart requirements, and coordinate power architecture with process continuity needs. | Controllers, industrial PCs, process monitoring, and equipment requiring controlled recovery. | Voltage dip and interruption testing, commonly addressed by GB/T 17626.11 / IEC 61000-4-11 for applicable equipment. |
| 10 | EMC testing and compliance engineering | Unverified emissions or immunity performance, and gaps between product design and applicable requirements. | Identify the applicable product and environment standards, establish a test plan, assess emissions and immunity, document results, and resolve failures through design changes and retesting. | New product development, design changes, production validation, and market-access preparation. | Relevant GB/T and IEC standards selected for the product; the GB/T 17626 series covers multiple immunity test methods. |