PM2.5 Fine particulate matter | About 0–1,000 µg/m³ for some optical instruments | Optical light scattering; reference methods may use filter-based gravimetric measurement | Ambient air, indoor air, smoke and process areas | Check low-concentration sensitivity and how humidity, particle composition, and aerosol type affect readings. Use an appropriate reference method when regulatory comparability is required. |
PM10 Inhalable particulate matter | About 0–10,000 µg/m³ for some optical instruments | Optical light scattering or size-selective filter sampling | Dusty workplaces, construction, ambient air and industrial processes | Confirm the instrument’s particle-size response and inlet design. A high upper range should not come at the expense of adequate resolution at expected concentrations. |
| Carbon monoxide (CO) | Common analyzer ranges include 0–50 ppm or 0–500 ppm | Electrochemical sensing or nondispersive infrared (NDIR) | Combustion areas, garages, boiler rooms and indoor environments | Choose a range and alarm settings suited to the applicable exposure limits and expected peaks. Check cross-sensitivity, response time, and calibration requirements. |
| Nitrogen dioxide (NO2) | About 0–1 ppm for some ambient analyzers; higher ranges are available for workplace instruments | Chemiluminescence analyzer or electrochemical sensor | Traffic-related air, combustion sources and occupational areas | Ambient monitoring may require very low detection limits. For electrochemical sensors, review potential interference from other gases and the need for periodic calibration. |
| Ozone (O3) | About 0–1 ppm for many monitoring applications | Ultraviolet photometry or electrochemical sensing | Ambient air, sterilization areas and ozone-generating processes | Select sensitivity appropriate to ambient or process levels. Check interference from other oxidizing gases and whether the instrument is suitable for continuous outdoor use. |
| Sulfur dioxide (SO2) | About 0–1 ppm for some ambient analyzers; higher ranges are available for source monitoring | Ultraviolet fluorescence or electrochemical sensing | Combustion emissions, industrial sites and ambient air | Match the range to expected concentrations and required detection limits. Consider sample-line materials, moisture management, and interference risks. |
Volatile organic compounds (VOCs) Total VOC indication | About 0–20 ppm, often reported as isobutylene equivalent, on some PID instruments | Photoionization detector (PID) | Solvent use, leak surveys, indoor investigations and industrial hygiene screening | A PID reading is not a compound-specific identification. Response varies by chemical; use suitable correction factors and laboratory analysis when individual compounds must be quantified. |
| Carbon dioxide (CO2) | Common indoor-air ranges include 0–5,000 ppm or 0–10,000 ppm | Nondispersive infrared (NDIR) | Occupied buildings, ventilation assessments and controlled environments | CO2 can help assess ventilation patterns but is not a direct measurement of all indoor pollutants. Consider accuracy, sensor placement, and outdoor baseline levels. |
| Hydrogen sulfide (H2S) | Common instrument ranges include 0–100 ppm; lower-range options may be available | Electrochemical sensing or colorimetric detector tubes | Wastewater facilities, confined spaces, oil and gas operations, and process areas | For worker protection, choose a suitable personal or area monitor and configure alarms according to applicable rules. Check sensor service life and cross-sensitivity. |