| Hydraulic pressure | 300–400 bar (30–40 MPa) is common in some high-pressure hydraulic systems; ratings vary by application and component. | Compare the drive’s continuous and intermittent pressure limits with the machine’s measured operating pressure and relief-valve setting. Do not treat a system pressure figure as an allowable drive rating. |
| Pressure type and duty cycle | Continuous, intermittent, and peak pressure are distinct ratings; allowable intermittent duration is product-specific. | Obtain the OEM rating definitions and limits. Account for pressure spikes during starts, turns, reversing, and track obstruction. |
| Hydraulic flow and speed | Motor speed depends on flow and displacement. For an ideal motor, speed in rpm ≈ 1,000 × flow (L/min) ÷ displacement (cm³/rev); actual speed is lower due to losses. | Match required travel speed and available flow to the drive’s approved operating range. Check case-drain and return-line requirements where applicable. |
| Required output torque | Hydraulic motor torque is related to pressure difference and displacement; gearbox reduction increases output torque while reducing output speed. | Check rated output torque and allowable peak torque against machine mass, gradeability, drawbar pull, and duty cycle—not pressure alone. |
| Gearbox and reduction ratio | Planetary reduction is commonly used in compact crawler travel drives; ratios and stage arrangements vary by design. | Verify output speed, torque capacity, gear life, and compatibility with the machine’s sprocket and track system. |
| Mounting and dimensions | Flange pattern, pilot diameter, bolt circle, shaft or spline, and overall envelope are application-specific. | Match the OEM drawing and measure the existing installation. Confirm clearance, fastener grade, and sprocket interface. |
| Brake configuration | Many crawler travel drives use a spring-applied, hydraulically released parking brake, but configurations differ. | Confirm brake torque, release pressure, porting, fail-safe behavior, and compatibility with the machine’s control circuit. |
| Oil, temperature, and cleanliness | Permitted oil viscosity, temperature range, and fluid cleanliness limits are specified by the component manufacturer. | Use the specified hydraulic fluid and filtration. Check operating temperature, flushing requirements, and contamination-control guidance. |
| Final compatibility check | Pressure, flow, torque, speed, mounting, brake, and duty-cycle limits must all be satisfied together. | Use the machine’s service documentation and the drive manufacturer’s current datasheet. Confirm the exact part specification before ordering or installation. |