| 1 | Hazardous-area certification | Confirm that the complete luminaire is certified for the intended hazardous location, not just that individual components are approved. | Check the certificate, product marking, applicable protection concept, and local requirements. ATEX, IECEx, and North American approvals are distinct systems and should not be treated as interchangeable. |
| 2 | Zone and material group | Match the luminaire’s marking to the site’s gas or dust classification, such as gas Zones 1 or 2 and dust Zones 21 or 22. | Verify the applicable gas or dust group against the hazardous-area classification documentation. A product suitable for one group or zone is not automatically suitable for another. |
| 3 | Temperature class and surface temperature | Check the marked temperature class or maximum surface temperature and compare it with the ignition-temperature limits of substances at the site. | For gas applications, common temperature-class limits include T4 at 135°C and T6 at 85°C. Confirm the required limit for the actual hazard and operating conditions. |
| 4 | Enclosure construction | Inspect the housing, joints, fasteners, glass or lens, and protective guard for robust construction and compatibility with the certified design. | Choose materials suited to the installation environment, such as corrosion-resistant metals or appropriately rated non-metallic components. Do not modify certified enclosures or replace parts with unapproved alternatives. |
| 5 | Heat control | Review heat-sink design, thermal paths, driver temperature limits, and rated ambient-temperature range. | Confirm that the stated temperature performance applies at the expected ambient temperature and installation orientation. Keep cooling surfaces clear and follow the manufacturer’s mounting and spacing instructions. |
| 6 | Ingress and impact protection | Check the IP rating for resistance to dust and water, plus the IK rating where mechanical impact is a concern. | For exposed or washdown locations, an IP66 rating may be appropriate, but verify the actual cleaning method and site conditions. IP and IK ratings do not replace hazardous-area certification. |
| 7 | Corrosion and chemical resistance | Assess exposure to salt spray, moisture, industrial chemicals, and corrosive atmospheres; check coatings, seals, and exposed hardware. | Ask for material and coating specifications relevant to the site. A product’s corrosion suitability depends on the specific chemicals, concentration, temperature, and exposure duration. |
| 8 | Cable entries and installation | Verify that cable glands, stopping plugs, conduit entries, and thread types are compatible with the luminaire certification and site wiring system. | Use correctly certified accessories with the required protection type and ingress rating. Installation and sealing should be performed according to the product instructions and applicable electrical codes. |
| 9 | Light output and beam distribution | Compare delivered lumens, beam angle, mounting height, glare, and required illuminance for the task area. | Use photometric data or a lighting calculation to confirm coverage. Higher wattage alone does not guarantee better illumination or fewer dark spots. |
| 10 | Serviceability and documentation | Review the operating instructions, inspection requirements, spare-part policy, warranty terms, and availability of certificates and technical data. | Plan maintenance without opening or repairing protected enclosures in ways that compromise certification. Keep inspection records and follow local hazardous-area maintenance procedures. |