| 1. Salt rejection | Rated NaCl rejection and expected permeate salinity | Many seawater RO elements report approximately 99.7%–99.8% rejection under specified test conditions. | Compare rejection figures only when test salinity, pressure, temperature, and recovery are comparable. Higher rejection can help meet product-water targets, but does not guarantee a specific output-water quality in every system. |
| 2. Water output | Permeate flow at the intended feed conditions | A preliminary seawater RO design flux is often around 12–18 L/m²·h; the suitable value depends on feed quality and plant design. | Check output at your actual salinity and temperature, not just the highest catalogue flow. Allow for seasonal changes and performance decline over time. |
| 3. Pressure needs | Operating pressure, pump capacity, and energy demand | Seawater RO systems commonly operate at roughly 55–70 bar (about 800–1,015 psi), depending on feed conditions and recovery. | Confirm the membrane can meet the required flow at the pressure your pump can supply. Colder water, higher salinity, or higher recovery can increase pressure requirements. |
| 4. Feed-water salinity | Total dissolved solids (TDS) and changes in source-water salinity | Open-ocean seawater is commonly near 35,000 mg/L TDS, though actual coastal and brackish-influenced sources vary. | Use a current feed-water analysis and account for seasonal variation. Do not assume a membrane’s rated flow at one salinity will hold at a higher site salinity. |
| 5. System recovery | Permeate produced relative to feed flow, and the resulting concentrate salinity | A preliminary single-pass seawater RO design may use about 35%–45% recovery; the appropriate target is site- and system-dependent. | Balance water yield against scaling risk, concentrate management, and pressure demand. Set recovery from water analysis and system design rather than maximizing it by default. |
| 6. Pretreatment and fouling risk | Suspended solids, turbidity, and silt density index (SDI) | An SDI₁₅ target below 3 is commonly used for RO feed pretreatment; the membrane supplier’s limits and project specifications should also be checked. | Choose the membrane as part of a complete pretreatment plan. Poor feed-water conditioning can reduce output and increase cleaning frequency regardless of the membrane’s rated rejection. |
| 7. Test conditions and normalization | How performance was measured and corrected for operating conditions | Published seawater RO test data may use conditions around 32,000 mg/L NaCl, 25°C, and 55 bar, but protocols differ between products and manufacturers. | Compare flow and rejection using the same feed concentration, temperature, pressure, and recovery wherever possible. Review normalized performance data and confirm the element fits the system’s pressure vessel. |