| Urban residential distribution | 10 kV / 0.4 kV | 315–1,250 kVA | Medium-voltage switchgear, distribution transformer and low-voltage board in a compact enclosure | Low noise, limited site footprint, safe public access and coordination with the local distribution network |
| Commercial buildings and shopping centers | 10 kV / 0.4 kV | 630–2,000 kVA | Incoming medium-voltage equipment, one or more transformers and outgoing low-voltage feeders | Load growth, ventilation or cooling, fire protection and access for inspection and replacement |
| Industrial plants and workshops | 10 kV / 0.4 kV | 800–2,500 kVA | Switchgear, transformer and low-voltage distribution sections; multiple units may be used for larger loads | Motor-starting demand, harmonic loads, protection coordination and separation of critical circuits |
| Public infrastructure and transport facilities | 10 kV / 0.4 kV | 400–1,600 kVA | Packaged transformer and switchgear arrangement supplying facility distribution boards | Continuity of service, emergency-load requirements, restricted access and environmental conditions at the site |
| Rural and peri-urban distribution | 10 kV / 0.4 kV | 100–630 kVA | Compact switchgear and transformer package sized to the local distribution load | Outdoor weather protection, maintainability, lightning protection and allowance for future demand |
| Solar photovoltaic plant auxiliary supply | Typically 10 kV / 0.4 kV for auxiliary loads | 100–1,000 kVA | Distribution transformer with medium- and low-voltage equipment for plant services | Dust and temperature exposure, remote monitoring and separation of auxiliary supply from generation step-up equipment |
| Wind farm auxiliary supply | Typically 10 kV / 0.4 kV for site services | 100–1,000 kVA | Packaged distribution equipment serving control buildings and other auxiliary loads | Wind, moisture, corrosion protection, remote operation and the project’s specific grid-connection design |
| Data centers and telecommunications facilities | 10 kV / 0.4 kV | 630–2,500 kVA | Transformer and distribution sections arranged to feed defined electrical load groups | Redundancy strategy, selective protection, heat management and coordination with backup power systems |
| Ports, logistics parks and large warehouses | 10 kV / 0.4 kV | 400–2,000 kVA | Medium-voltage incoming section, transformer and low-voltage feeder board | Outdoor exposure, vehicle access, enclosure placement and provision for changing operational loads |
| Temporary construction and project sites | 10 kV / 0.4 kV, where network conditions permit | 100–1,000 kVA | Transportable packaged equipment with distribution outlets or feeder connections | Relocation needs, cable routing, mechanical protection and compliance with temporary-site electrical rules |