| 4–20 mA Loop Calibrator | DC current, loop power, percentage output, transmitter simulation | 0–24 mA; commonly supports 12–30 V DC loop power | Approximately ±0.05% to ±0.1% of reading | Testing flow, pressure, level and temperature transmitters; commissioning and troubleshooting control loops | Loop power capability, HART-compatible loop resistance, battery life, overload protection and intrinsically safe options |
| Multifunction Electrical Process Calibrator | DC voltage, DC current, resistance, frequency and pulse signals | Typically 0–10 V, 0–24 mA, resistance from tens of ohms to several kilohms, and frequency from low hertz to several kilohertz | Approximately ±0.02% to ±0.1% of reading, depending on function | Calibration of PLC analog inputs, signal conditioners, data acquisition systems and control panels | Source and measure modes, isolated channels, resolution, output stability and calibration certificate traceability |
| Temperature Process Calibrator | RTD, thermocouple, thermistor and temperature transmitter signals | RTD and thermocouple simulation; common sensor types include Pt100, K, J, T, E, N, R and S | Electrical simulation commonly ±0.2–1.0 °C; actual accuracy depends on sensor type and temperature range | Verification of temperature transmitters, thermocouple inputs, RTD circuits, ovens and process temperature loops | Supported sensor standards, cold-junction compensation, three- or four-wire RTD measurement and high-temperature stability |
| Pressure Calibrator | Gauge, absolute and differential pressure; pneumatic or hydraulic generation | From vacuum ranges around −0.1 MPa to positive ranges commonly between 1 MPa and 70 MPa, depending on the pressure module or pump | Approximately ±0.05% to ±0.25% of full scale for typical field instruments | Calibration of pressure transmitters, gauges, switches, safety systems and hydraulic or pneumatic instruments | Pressure range, media compatibility, leak rate, module interchangeability, overpressure protection and pump type |
| Documenting Multifunction Calibrator | Current, voltage, resistance, frequency, RTD and thermocouple signals; some models support digital transmitter communication | Usually combines 0–24 mA, 0–10 V, thermocouple and RTD functions in one handheld instrument | Approximately ±0.02% to ±0.1% of reading, depending on the selected function | Routine maintenance, loop commissioning, calibration data recording and multi-parameter field service | Internal memory, calibration procedures, USB data transfer, display readability, communication support and certificate management |
| Dry-Block Temperature Calibrator | Controlled temperature generation for temperature sensors and switches | Common working ranges include approximately −30 °C to 1,200 °C, depending on the heating or cooling design | Typical stability and uniformity are about ±0.1 °C to ±0.5 °C in suitable operating ranges | Testing RTDs, thermocouples, temperature switches and thermal instruments in laboratories and industrial plants | Temperature range, well diameter, loading effect, stability, uniformity, ramp time and reference sensor compatibility |
| Electrical Safety and High-Voltage Calibrator | Insulation resistance, leakage current, voltage and electrical safety test parameters | Common insulation test outputs range from several hundred volts to around 1,000 V DC, depending on the instrument | Usually specified separately for voltage, resistance and leakage-current functions | Verification of electrical safety testers, control cabinets, motors, power supplies and industrial equipment | Output safety, discharge function, measurement category, insulation resistance range, interlock design and applicable test procedures |