| General rotating-machine condition checks | Typically 10–1,000 Hz for common vibration-severity measurements; confirm the range for the machine and assessment method. | Vibration meter or data collector with an accelerometer. Measure overall RMS velocity and, where useful, acceleration and displacement. | As a purchasing target, look for amplitude accuracy of about ±5% of reading within the stated calibrated frequency band. Check the complete instrument-and-sensor specification. | ISO 20816 series for machine vibration evaluation, with the applicable part selected for the machine type; ISO 2954 for vibration-severity measuring instrument requirements. |
| Slow-speed machines and low-frequency motion | Often approximately 0.1–100 Hz, depending on shaft speed, structural response, and the frequencies of interest. | Low-frequency accelerometer or velocity sensor paired with a meter or analyzer that supports the required low-frequency response. Displacement may be useful at very low frequencies. | Verify the lower frequency limit, sensor sensitivity, mounting method, and noise floor. A nominal range alone does not establish accuracy near the instrument’s low-frequency cutoff. | Use the applicable part of the ISO 20816 series where relevant. ISO 16063 series describes calibration methods for vibration and shock transducers. |
| Bearing and gear fault investigation | Commonly 1–10 kHz for high-frequency vibration or resonance analysis; the required upper limit depends on the fault and sensor. | Portable vibration analyzer or condition-monitoring system with a suitable accelerometer, spectral analysis, and optional envelope or demodulation processing. | Check usable frequency response, sampling rate, anti-alias filtering, sensor resonance, and mounting. Select a frequency range that includes the signal of interest with margin. | ISO 13373-1 provides general guidance for vibration condition monitoring of machines. It does not set universal fault-frequency limits or acceptance thresholds. |
| Whole-body human vibration | Typically 0.5–80 Hz for the frequency range associated with whole-body vibration measurement, subject to the required weighting and instrument specification. | Human-vibration meter with a suitable seat-pad or platform transducer and the required frequency weightings. | Use an instrument that meets the applicable human-vibration instrument requirements. Confirm weighting functions, measurement axes, transducer type, and calibration status. | ISO 8041-1 covers instrumentation for measuring human response to vibration; use the applicable exposure-assessment standard for the specific task. |
| Hand-transmitted vibration | Commonly about 6.3–1,250 Hz for hand-arm vibration measurement, depending on the instrument and required weighting. | Human-vibration meter with a suitable hand-arm transducer and frequency weighting, mounted using an appropriate adapter. | Prioritize compliance with the relevant instrument requirements, correct sensor mounting, axis orientation, and measurement procedure rather than relying on a single accuracy figure. | ISO 8041-1 covers human-vibration measurement instrumentation; ISO 5349-1 gives general requirements for measuring and evaluating hand-transmitted vibration. |
| Structural testing and modal analysis | Application-dependent: from below 1 Hz to several kHz, depending on the structure, excitation, and modes being investigated. | Multi-channel vibration analyzer with accelerometers or a non-contact vibration sensor. Measure time histories, frequency spectra, and frequency-response functions as required. | Consider amplitude and phase accuracy, channel synchronization, sensor mass loading, and calibration. Measurement uncertainty should be appropriate to the test objective. | ISO 7626 series covers experimental determination of mechanical mobility; ISO 16063 series provides transducer calibration methods. |